Specifications
  • S-type load cell has capacity: 20 kg...30 ton
  • Alloy steel or stainless steel material, welded sealing, oil-proof, water-proof, anti-corrosion

Specifications

Capacity

  • 20 - 500 kg

Output

  • 2 ± 0.004 mV/V
  • 3 ± 0.004 mV/V

Combined Error

  • 0.03 % Full Scale (Option: OIML C3)

Non-Linearity

  • ± 0.02 % Full Scale

Hysteresis

  • ± 0.02 % Full Scale

Repeatability

  • ± 0.01 % Full Scale

Creep

  • ± 0.02 % Full Scale/30 min

Zero Unbalance

  • 1 % Full Scale

Excitation Voltage

  • 5 Vdc ~ 15 Vdc

Operating Temperature Range

  • -35 ~ +80° C

Compensated Temperature Range

  • -10° ~ +55° C

Temperature Coefficient of Zero

  • 0.02 % Full Scale/10° C

Temperature Coefficient of Span

  • 0.03 % Full Scale/10° C

Input Resistance

  • 360 ± 10 Ω

Output Resistance

  • 350 ± 10 Ω

Insulation Resistance

  • ≥ 5000 MΩ @ 50 Vdc

Safe Load

  • 150 % Full Scale

Ultimate Overload

  • 200 % Full Scale

Protection

  • IP67

Electrical Resistance

  • 4-core Shielded Cable, Diameter: 5.7 mm, Length: 3.5 m (0.75 ~ 2 t), 6 m (3 ~ 10t)

  • Used for Compression Tension Measurement, Easy Installation

Documentation