UltraPro 500 Ultrasonic Level Sensor
Brand: Icon Process ControlThe UltraPro Ultrasonic level Sensors are 2-Wire loop powered sensors designed provide reliable accurate level measurement, flow monitoring, and volume of liquid in tanks, pits, sumps and open channels.
The UltraPro series are very reliable and offer both 4-20mA analog output with HART® protocol or output RS-485 Modbus.
The UltraPro Series are designed to work with most types of remote instrumentation and provide enhanced functionality such as remote displays and remote monitoring solutions.
Features- Push Button Programming
- Narrow Beam Technology
- General Purpose | XP Explosion Proof
- 2 Wire (4-20 mA) + (HART) Output Signal
- Measuring Range: 4″ - 66 Ft
- Accuracy: 0.2%
Displaying prices & availability for Ohio, United States in USD. Change location.
Models matching criteria: 5
UltraPro 500 Ultrasonic Level Sensor
view more
- Range: 1 m | 3.3 ft
- Connection: ¾" Threaded
In Stock
Does not ship to OH, United States
UltraPro 500 Ultrasonic Level Sensor
view more
- Range: 2 m | 6.6 ft
- Connection: 1" Threaded
In Stock
Does not ship to OH, United States
UltraPro 500 Ultrasonic Level Sensor
view more
- Range: 6 m | 19.7 ft
- Connection: 1½" Threaded
In Stock
Does not ship to OH, United States
UltraPro 500 Ultrasonic Level Sensor
view more
- Range: 10 m | 32.8 ft
- Connection: 2¼" Threaded
In Stock
Does not ship to OH, United States
UltraPro 500 Ultrasonic Level Sensor
view more
- Range: 20 m | 65.6 ft
- Connection: 3" Flanged
In Stock
Does not ship to OH, United States
Specifications
Brand
Operating Range
- 0.1 to 65 ft (0.03 to 20 m)
Working Frequency
- 4-20 mA
Resolution
- < 1 mm | 0.04”
Accuracy
- 1 m | 0.2 % || 2 m | 0.15 % || 6 m | 0.15 % || 10 m | 0.2 % || 20 m | 0.2 %
Temperature Error
- Maximum 0.04 % | K
Maximum Overpressure
- 0.1 MPa
Beam Width
- Size Dependant
Measuring Period
- 1 m (0.5 s), 2 m (0.5 s), 6 m (1.2 s), 10 m (1.2 s), 20 m (5 s)
Maximum Current Output Load
- @ U = 24 Vdc Rmax = 270 Ω | @ U = 22 Vdc Rmax = 180 Ω | @ U=20 Vdc Rmax = 90 Ω
Delay Between Rise Time
- 1 m (5 s), 2 m (5 s), 6 m (5 s), 10 m (9 s), 20 m (9 s)
Minimum Voltage Load
- Rmin > 1k Ohm
Enclosure Rating
- NEMA 4X | IP67
Materials
- Sensor Body: PVDF
- O-Rings: FKM
- Housing: ABS
Electrical
- Output: 4-20 mA (Limit values 3.9 - 20.5 mA), HART RS-485 with protocol Modbus RTU
- Supply Voltage: 18 to 36 Vdc ± 10 % regulated
- Supply Voltage: 4-20 mA | Max. 22 mA (0-10 V - limit values 0 -10.2 V)
Operating Temperature
- PVDF: -22° F to 158° F (-30° C to 70° C)
- ABS: 32° F to 140° F (0° C to 60° C)
Standards & Approvals
- CE
- FCC
- RoHS Compliant
- Chemical Storage Tanks
- Waste Sumps
- Bulk Storage
- Tanker Truck
- Day Tank
- Process Tank
- Neutralization Tank
- Open Channel
- Chemical Feed and Clarifier Applications