Price
Request a Quote
Stock
In Stock

  • Model & Function - (N.C.) Normally Closed - Low Alarm, 28° Switching Differential
  • Cable Length - 40 Feet (12 metres)

Specifications

Cable

  • TLS-6A/B: 2/C 0.5mm², ~20 AWG
  • TLS-8A/B: 2/C 0.75mm², ~18 AWG
  • TLS-6-B: 2/C 1.25mm², ~16 AWG

Cable Weight

  • TLS-6A/B: Painted cast iron
  • TLS-8A/B: Painted cast iron
  • TLS-6-B: 1.1 lbs, 0.5 kg, Polypropylene

Contact Rating

  • TLS-6A/B: Max. 50 VA AC/50W DC
  • TLS-8A/B: Max. 50 VA AC/50W DC
  • TLS-6-B: Max 10 A @ 250VAC
  • 50/60 Hz

Current Rating

  • TLS-6A/B: Max. 0.5 AC/DC
  • TLS-8A/B: Max. 0.5 AC/DC
  • TLS-6-B: Max 10 A @ 250VAC

Housing

  • TLS-6A/B: Polypropylene with ABS Resin cap
  • TLS-8A/B: ABS Resin
  • TLS-6-B: Polypropylene

Liquid Operating Temperature

  • TLS-6A/B: 14°F to 122°F, -10°C to 50°C
  • TLS-8A/B: 14°F to 122°F, -10°C to 50°C
  • TLS-8A/B -T: 14°F to 158°F, -10°C to 70°C
  • TLS-6-B: 32°F to 140°F, 0° to 60°C

Maximum Pressure

  • TLS-6A/B: 29 psi, 2 bar
  • TLS-8A/B: 29 psi, 2 bar
  • TLS-6-B: 28 psi, 1.9 bar

Maximum Water Depth/Cable Length

  • TLS-6A/B: 65.6 ft, 20 m
  • TLS-8A/B: 65.6 ft, 20 m
  • TLS-6-B: 19.7 ft, 6 m

Minimum Specific Gravity

  • TLS-6A/B: 0.7
  • TLS-8A/B: 0.9
  • TLS-6-B: 0.6

Protection

  • IP68

Standard Cable Length

  • 6m, 19.7 ft

Switching Differential

  • TLS-6A/B: 11” - 39”, 0.27m - 1m
  • TLS-8A/B: 13” - 157”, 0.33m - 4 m
  • TLS-6-B: 28° ±2°

Voltage

  • TLS-6A/B: Max. 300 VAC/VDC
  • TLS-8A/B: Max. 300 VAC/VDC
  • TLS-6-B: Max. 250 VAC/VDC

Documentation

show more