Accuracy
- ± 0.075 % - Nominal Measuring Range 0 to 25 Mbar & -100 to 100 Mbar
- ± 0.1 % - Nominal Measuring Range -7 to 7 Mbar & -25 to 25 Mbar
- ± 0.16 % - Nominal Measuring Range -2.5 to 2.5 Mbar
Ambient Temperature Range
- -25° to 85° C (-13° to 185° F)
Applications
- Chimney Draughts
- Differential Pressure Measurement
- Flow Measurement
- Level Measurement
- Pressure / Underpressure in Furnace Chambers
Approvals & Certifications
- ATEX Intrinsically Safe
- Ex II 1/2 G Ex ia IIC T4/T5 Ga/Gb, II 1/2 G Ex ia IIB T4/T5 Ga/Gb, II 1D Ex ia IIC T105° C Da
Compensated Temperature
- -10° to 70° C (14° to 158° F)
Damping Adjustment
- Additional Electronic: 0 to 60 seconds
Electrical Connectors
- 1/2” NPT Female
- M20 x 1.5 Packing Gland
Enclosure, Body Material
- 316 Stainless Steel
- Aluminum
Flange Material
- Cover Flange: 316L Stainless Steel
Materials of Construction
- Adapter C, GP & P Typical: 316 Stainless Steel
- Adapter PCV Typical: Brass
Mounting
- 2” Pipe Mounting Bracket of Zinced Steel or Stainless Steel Material
- Wall Mounting Bracket
Operating Temperature
- -25° to 85° C (-13° to 185° F)
Overpressure & Static Pressure Limits
- psi: 5.07 to 14.5 (kPa: 35 to 100, bar: 0.35 to 1)
Power Supply
- 12-55 Vdc (EEx 13.5-28 V)
Power Supply Effect
- 0.002 % of Full Scale Output/V
Pressure Range
- kPa: -10 to 10
- mbar: -100 to 100
- psi: -1.45 to 1.45
Resistance
- Communication: 250 to 1,100 ohms
Rotation
- Casing: 0° to 355°
- Display: 90°
Temperature Effect
- ≤ ± 0.1 % of Full Scale Output/10° C (18° F)
- Maximum
Voltage Drop
- 3 V, when Display Illumination Switched On