LM6 All Stainless Steel Submersible Transmitter

Brand: Winters Instruments

Specifications
  • Designed for continuous level measurement in water or other liquids with low viscosity 
  • 316L Stainless Steel probe with stainless steel sensor for ease of cleaning 
  • Available ranges from Inches WC: 0 to 400 up to psi: 0 to 300 (kPa: 0 to 2,068, bar: 0 to 20.68) 
  • ±0.1% to ±0.35% accuracy ratings 
  • NEMA 6P / IP68. Approved for outdoor use 
  • Customizable 

Models matching criteria: 14
  • Pressure Range - Inches WC: 0 to 200
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 25
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 15
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 200
In Stock
Does not ship to VA, United States
  • Pressure Range - Inches WC: 0 to 50
In Stock
Does not ship to VA, United States
  • Pressure Range - Inches WC: 0 to 100
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 5
In Stock
Does not ship to VA, United States
  • Pressure Range - Inches WC: 0 to 300
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 10
In Stock
Does not ship to VA, United States
  • Pressure Range - Inches WC: 0 to 150
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 300
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 50
In Stock
Does not ship to VA, United States
  • Pressure Range - psi: 0 to 100
In Stock
Does not ship to VA, United States
  • Pressure Range - Inches WC: 0 to 400
In Stock
Does not ship to VA, United States

Specifications

Accuracy

  • < ± 0.35 % of Full Scale Output
  • All Nominal Pressure: < ± 0.1 % of Full Scale Output BFSL
  • Nominal Pressure psi: ≥ 5 (kPa: 34.47, bar: 0.3447): < ± 0.25 % of Full Scale Output BFSL

Approvals & Certifications

  • CE
  • CSA
  • EMC (Electromagnetic Compatibility): Emission & Immunity According to EN 61326
  • RoHS

Burst Pressure

  • psi: 22 to 1,740 (kPa: 151.7 to 12,000, bar: 1.517 to 120)

Cable Material

  • Cable with Sheath: FEP (Black)
  • Cable with Sheath: PUR (Black)
  • Cable with Sheath: PVC - Grey

Capacitance

  • Cable Capacitance (Signal Line / Shield & Signal Line / Signal Line): 160 PF/m

Circuit Protection

  • Reverse Polarity Protection

Compensated Temperature

  • 0° to 70° C (32° to 158° F)

Consumption

  • Current Consumption, Current: 25 mA - Max.
  • Current Consumption, Voltage: 7 mA - Max.

Diaphragm Material

  • 316L Stainless Steel

Enclosure, Body Material

  • 316L Stainless Steel

Environmental Protection

  • IP67
  • IP68
  • NEMA 6P

Inductance

  • Cable Inductance (Signal Line/Shield & Signal Line/Signal Line): 1 µH/m

Load

  • Current 3-Wire: Rmax = 500 ohms
  • Voltage 3-Wire: Rmin = 10 kiloohms

Load Effect

  • 0.05 % of Full Scale Output / kiloohms

Nominal Pressure

  • psi: 0 to 5 (kPa: 0 to 34.47, bar: 0 to 0.344)

Output

  • 2-Wire: 4-20 mA/Vs = 8-32 Vdc
  • 3-Wire: 0-10 V/Vs = 14-30 Vdc
  • 3-Wire: 0-20 mA/Vs = 14-30 Vdc

Overpressure & Static Pressure Limits

  • Overpressure psi: 7 to 1,160 (kPa: 48.26 to 8,000, bar: 0.482 to 80)

Power Supply Effect

  • 0.05 % of Full Scale Output / 10 V

Pressure Range

  • bar: 0 to 20.68
  • Inches WC: 0 to 400
  • kPa: 0 to 2,068
  • psi: 0 to 300

Process Temperature

  • -10° to 70° C (14° to 158° F)

Response Time

  • ≤ 10 milliseconds
  • Accuracy < ± 0.1 % of Full Scale Output: 200 milliseconds

Seat / Seal Material

  • Seal: FKM

Sensor, Probe Material

  • Probe: 316L Stainless Steel
  • Sensor: Stainless Steel for Ease in Cleaning

Stability

  • Long Term Stability: < ± 0.1 % of Full Scale Output/Year

Storage Temperature

  • -25° to 70° C (-13° to 158° F)

Temperature Effect

  • Tolerance Band: 5 (kPa: 34.47, bar: 0.344)
  • Tolerance Band: < ± 1 % of Full Scale Output for Nominal Pressure psi: < 5 (kPa: 34.47, bar: 0.344)

  • Designed for Continuous Level Measurement in Water or other Liquids with Low Viscosity
  • Sewage Treatment Measurement
  • Typical Installations Include Ground or Tank Level Monitoring of Water

show more