Capacitive Differential Pressure Transmitter

Brand: Xi'an UTOP Measurement Instrument Co, Ltd

UIB3351 Capacitive Differential Pressure Transmitters are suitable for the measurement of flow, level and pressure (differential pressure, gauge pressure and absolute pressure), this product has strong adaptability and high reliability, and also has good anti-interference ability and zero stability.

Its accuracy reaches 0.1%FS. 3351 can be made with HART Protocol communication, can be communicated with many hand-held communicator like HK- 375 & Rosemount 275 etc.

UIB3351 Capacitive Differential Pressure Transmitters is composed of pressure sensor and PCB.

The pressure sensor includes sensing element, EEPROM and other parts; PCB includes micro processor, digital/analogue converter, digital communication and memory EEPROM etc, to complete the conversion from pressure signal to 4~20 mA DC signal.
Features
  • Adopting microprocessor to improve its flexibility and functions
  • Have strong self-diagnostic capability
  • Wide ranges from 0~100 Pa to 42 MPa
  • Accuracy better than 0.1% FS or 0.2% FS, rangeability 15:1
  • Zero and span adjustment without mutual influence
  • Have prefect remote setting, local setting as well as adjustment function
  • 2-wire system, HART Protocol
  • Use digital compensation technology to compensate for temperature and system pressure error
  • Good stability, high accuracy, adjustable damping, strong unidirectional overload capacity
  • No mechanical transmission parts, little repair work, strong vibration resistance
  • All general parts, convenient maintenance
  • Optional of diaphragm material (contact medium), explosion-proof
  • Super performance and reliability

Specifications

Pressure Ranges

  • 0 ~ 0.1 kPa...40 MPa

Accuracy

  • 0.1 % Full Scale, 0.2 % Full Scale

Output

  • 2-Wire 4~20 mA, and Superimposes Conforms to HART Protocol

Rangeability

  • 15:1

Power Supply

  • 12~45 Vdc, Standard 24 Vdc

Load Resistance

  • The Max. Allowed Load Resistance on Circuit is Determined by Power Supply, For HART, 250 Ω ≤ Load Resistance ≤ 1100 Ω

Indicator

  • 0 ~ 100 Linear Meter or Digital Indicator

Temperature Effect

  • < 0.03 % Full Scale/10 for GP/DP Transmitter

System Pressure Effect

  • ± 0.25 % Full Scale/10 MPa for DP Type (can be revised in Pipeline Pressure)
  • ± 0.2 % Full Scale/32 MPa for HP Type (can be revised in Pipeline Pressure)

EMI /RFI Interference Effect

  • 20~1000 MHz, Output Drift less than 0.01 % Full Scale if Field Intensity reach 30 V/m

Mounting Position Effect

  • Maximum 0.24 kPa. When Liquid Membrane is Mounted Horizontally, Zero Drift at most 1.25 kPa.
  • Zero Drift can be Modified and Without any Influence for Range

Temperature Range

  • Ambient Temperature: -40° C ~ +85° C, -20° C ~ +65° C (For Indicator)
  • Medium Temperature Range: -40° C ~ +120° C
  • Storage Temperature Range: -40° C ~ +105° C

Relative Humidity

  • 0 ~ 100 % Relative Humidity

Weight

  • 3.5 kg (Standard Configuration without Mounting Kits, Height: 190 mm)

Electrical Connection

  • M20 x 1.5 or 1/2” NPT

Process Connection

  • 1/4” NPT Female Connector

Diaphragm Material

  • 316L, Hastelloy C-276, or Monel

Vent/Drain Value

  • 316L, Hastelloy C-276, or Monel

O-ring Materials

  • Nitrile Rubber, Fluorine Rubber, Teflon, Metal Sealing Ring

Electronic Shell and Coating

  • Low Copper Alloy, Anodic Oxidation, Spraying Polyurethane

Sensor Filling Liquid

  • Silicone, Fluorosilicone Oil

Meter Cover and Display Box

  • 10 mm Toughened Glass, Nitrile Rubber Seal

Protection

  • IP67

Explosion-Proof

  • Intrinsic Safety: Exia II Ct6
  • Flame Proof:Exd II CT6

show more