DPR-2000 SMART Differential Pressure Transmitter

Brand: Delta Mobrey

The model DPR-2000 Differential Pressure Transmitter is suitable for measuring pressures from -100 mbar to 70 bar with maximum working pressures up to 420 bar. 

The DPR-2000 SMART Differential Pressure Transmitters are suitable for measuring differential pressure of gases, vapours and liquids. 

The active sensing element is a piezoresistive silicon sensor separated from the medium by a diaphragm and by a specially selected type of manometric liquid. The special design of the active sensing element ensures that it is able to withstand pressure surges and overloads of up to 250/320/420 bar. 

The casing is made of cast Aluminum alloy or 316 stainless steel with degree of protection IP66/IP67. The design of the casing enables the use of a local display, rotation of the display by 90°, rotation of the casing by 0 to 355° relative to the sensor, and a choice of cable direction.

Specifications

Accuracy

  • ≤ ± 0.075 % of Calibrated Range
  • ≤ ± 0.1 % of Calibrated Range - Measuring Range -20 to 20 Mbar (Range No 9)

Applications

  • Differential Pressure Measurement
  • Flow Measurement
  • Level Measurement

Approvals & Certifications

  • ATEX Intrinsically Safe, Flameproof
  • Ex I M1 Ex ia I Ma, Ex II 1/2 G Ex ia IIB T4/T5 Ga/Gb & Ex II 1D Ex ia IIIC T105° C Da
  • Ex I M2 Ex d Ia I Mb, Ex II 1/2 G Ex ia/d IIC T6/T5 Ga/Gb & Ex II 1/2 D Exia/tII IC T85° C/T100° C Da/Db

Communication

  • Bluetooth
  • HART
  • USB

Compensated Temperature

  • -25° to 80° C (-13° to 176° F)

Damping Adjustment

  • Additional Electronic: 0 to 60 seconds

Diaphragm Material

  • 316L Stainless Steel
  • Gold-Plated (Au)
  • Hastelloy C-276

Display

  • Backlit LCD Display
  • Local Display

Electrical Connectors

  • 1/2” NPT Female
  • M20 x 1.5 Packing Gland

Enclosure, Body Material

  • 316 Stainless Steel
  • Aluminum

Environmental Protection

  • IP66
  • IP67

Flange Material

  • Cover Flange: 316 Stainless Steel

Gasket Material

  • FPM Viton
  • NBR

Media

  • Gas
  • Liquids
  • Vapor

Metric Connection

  • Cover Flange: M10
  • M20 x 1.5 Male

Mounting

  • 2” Pipe Mounting Bracket of Zinced Steel or Stainless Steel Material

Name Plate, Tag Material

  • Stainless Steel

NPT Connection

  • 1/4” NPT Female

Operating Pressure

  • psi: 0 to 6,092 (kPa: 0 to 42,000, bar: 0 to 420)

Operating Temperature

  • -25° to 75° C (-13° to 167° F) - Exd Version
  • -25° to 80° C (-13° to 176° F) - Exi Version
  • -25° to 85° C (-13° to 185° F)

Output

  • 0-20 mA - DPR-2000ALE
  • 4-20 mA, 2-Wire

Overpressure & Static Pressure Limits

  • Static Pressure psi: 0 to 6,092 (kPa: 0 to 42,000, bar: 0 to 420)

Power Supply

  • 12-36 Vdc - Model DPR-2000ALE
  • 12-55 Vdc (Ex ia 13.5-28 V & Ex d 13.5-45 V) - Model DPR-2000ALW

Power Supply Effect

  • 0.002 % of Full Scale Output/V

Pressure Range

  • bar: -0.1 to 70
  • kPa: -10 to 7,000
  • psi: -1.45 to 1,015

Process Temperature

  • -25° to 120° C (-13° to 248° F)

Resistance

  • Communication: 250 to 1,100 ohms

Rotation

  • Casing: 0° to 355°
  • Display: 90°

Stability

  • Long Term: ≤ ± 0.075 % of Calibrated Range for 3-Years - Nominal Measuring Range

Temperature Effect

  • ≤ ± 0.03 % of Full Scale Output/10° C (18° F) - Special Version for Measuring Range 0-70 bar to -5 to 70 Mbar (Range No 1 to 8)
  • ≤ ± 0.05 % of Full Scale Output/10° C (18° F) - Measuring Range 0-70 bar to -5 to 70 Mbar (Range No 1 to 8)
  • ≤ ± 0.08 % of Full Scale Output/10° C (18° F) - Measuring Range -20 to 20 Mbar (Range No 9)
  • Maximum

UNF/UNC Connection

  • Cover Flange: 7/16” UNF

Voltage Drop

  • 3 V, when Display Illumination Switched On

Wetted Materials

  • 316 Stainless Steel - Typical C Process Connection
  • 316L Stainless Steel - Typical P, PN Process Connection
  • Hastelloy C-276 - Typical P(H) Process Connection

Window Material

  • Hardened Glass
  • Polycarbonate Glass

Zero Offset

  • Static Pressure: 0.01 % of Full Scale Output/10 bar - Measuring Range -0.5 to 2.5 bar
  • Static Pressure: 0.03 % of Full Scale Output/10 bar - Measuring Range -100 Mbar to 70 bar
  • Static Pressure: 0.08 % of Full Scale Output/10 bar - Measuring Range -100 Mbar to 16 bar

  • Measuring Differential Pressure, Level & Flow

show more