Type ATL Rail-Mounted Temperature Transmitter

Brand: Aplisens S.A.

The temperature economical transmitter ATL is applicable to converting resistance of temperature sensor to standard current signal 4…20 mA.

Most of parameters such as: sensor type, input signal, measuring range may be adapted by user for specific requirements of his measuring system.

The transmitter is programmed using PC with RS converter and Aplisens AT configuration software.

If you define type of sensor, measuring range in the order, then the transmitter is programmed with required parameters and their values are printed on serial number label.

Transmitter for rail mounting.
Features
  • Programmable sensor type PT100, Ni100
  • Programmable measuring range
  • Thermoresistance line compensation (3 wires line)
  • Output signal 4…20 mA
  • Rail-mounting system

Specifications

Power Supply

  • 6-29 Vdc

Limit Process

  • 20 Ω < R < 380 Ω

Input Signal

  • Pt100, Ni100

Output Signal

  • 4-20 mA

Ambient Temperature

  • -25° to 80° C

Minimum Measuring Range

  • 10 Ω

Alarm Signal

  • 3.8 mA, 23 mA

Accuracy

  • ± 0.2 %

Thermal Error

  • ± 0.1 % / 10° C

show more