NC-15/25 Plastic Level Switch

Brand: Icon Process Control

Specifications
  • Fit a Wide Range of Tubing Diameters – ¼″ to ½″
  • Flow – No Flow
  • Mounting Bracket
  • Easy Install
  • High Accuracy

Models matching criteria: 2
FloatPro Ball Float Valve show more
  • Sensing Method: Electrostatic Capacitive Method
  • Applicable Tube Diameters: ¼" - ½"
  • Output Configuration: NPN | PNP Output
In Stock
Does not ship to OH, United States
FloatPro Ball Float Valve show more
  • Sensing Method: Photoelectric Method
  • Applicable Tube Diameters: ¼" - ½"
  • Output Configuration: NPN | PNP Output
In Stock
Does not ship to OH, United States

Specifications

Applicable Pipes Size

  • Materials: Polycarbonate
  • Diameter: 3/8” - 1/2” (7 to 13 mm)
  • Wall Thickness: 0.62”

Sensing Object

  • Liquid

Repeat Accuracy

  • ± 0.2 mm max

Power Supply Voltage (Operating Voltage Range)

  • 12 to 24 Vdc | 10 % Max. ripple | (10.8 to 30 Vdc)

Current Consumption

  • 12 mA max

Relay Output

  • Load Current: NPN | PNP (100 mA max)
  • Residual Voltage: 1 V Max. (Load current: 100 mA, Cable length: 2 m)

Sensing Liquid Position

  • Indented mark position

Indicators

  • Detection indicator (orange)

Ambient Temperature Range

  • Operating: 0° C to 55° C (with No icing or condensation)
  • Storage: -10° C to 65° C (with No icing or condensation)

Ambient Humidity Range

  • Operating | Storage: 25 % to 85 % (with no condensation)

Temperature Influence

  • ± 4 mm of detection level at 23° C in the temperatureRange of 0° C to 55° C (with pure water or 20 % saline solution)

Voltage Influence

  • ± 0.5 mm of detection level at the rated voltage in rated voltage ± 10 % range

Insulation Resistance

  • 50 MΩ minimum (at 500 Vdc) between current-carrying parts and case

Dielectric Strength

  • 500 Vac, 50/60 Hz for 1 min between current-carrying parts and case

Vibration Resistance

  • Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock Resistance

  • Destruction: 500 m/s² 3 times each in X, Y, and Z directions

Degree of Protection

  • IP66 (IEC)

Connection Method

  • Pre-Wired Models (Standard cable length: 2 m)

Weight (Packed State)

  • Approx. 70 g

Materials

  • Case, Cover: Heat-Resistant PC
  • Cable Clamp: Nylon

Accessories

  • Two bands

show more