The “OCD Xtra” combines multiple light wavelengths with multiple sensor technology, to measure oil accurately in the range 0-200 ppm, even in the blackest of produced water.

Multiple oil types are automatically compensated for by sophisticated algorithms. The multi – parameter display shows the sample’s oil content, pressure and a graphical average of the last 4 hours oil readings.

The last 7 days readings are stored in ROM and can be accessed from the help menu.

The OCD Xtra has the ability to adjust the calibration settings against laboratory analysis on site. Full on screen help is available to guide the operator during set-up and maintenance routines

Specifications

Oil Types

  • Factory calibrated on up to 6 different oil types

Clean Water Calibration

  • ± 10 ppm of factory set values

Oil Range

  • 0 - 200 ppm

Resolution

  • 1 ppm, 1ntu

Accuracy Oil Range

  • ± 5 ppm up to 50 ppm thereafter 10 % of Reading

Solids Discrimination

  • 100 ppm Min. (Any calibrated solid type)

Oil Alarm Setpoints

  • 2 x 1 - 200 ppm - user adjustable

Alarm Contacts

  • 2 single pole Alarm Relays 8A @ 250 V ac

Fault Contact

  • 1 Single pole Alarm Relay 8A @ 250 V ac

Analogue Output

  • isolated 0-20 mA, 4-20 mA, 0-5 V dc

Remote Input

  • Remote Start / Stop function available with latching switch

Ambient Humidity

  • 90 % Relative Humidity Max. @ 50° C / 122° F

Ambient Temperature

  • 0° to 45° C

Sample Temperature

  • 0° to 50° C

Sample Flow Rate

  • 0.5 - 4 L per min / 0.13 - 1.06 gal per min

Sample Pressure

  • 3 - 10 bar

Protection Class

  • IP65

Approvals

  • Tested to EN 61010 EN 61326 (CE)

Weight

  • 25 kg / 55 lb

Supply Voltage

  • 24 V ac, 115 or 230 V ac, 50/60 Hz (± 10 %)

Consumption

  • 60 VA max

Auto Clean Air Supply (Pneumatic Only)

  • 4 bar / 58 psi

show more