SGE-25/HASTELLOY Hydrostatic Level Probe

Brand: Aplisens S.A.

Specifications
  • All wetted parts made in Hastelloy
  • Any measurement range from 2 up to 20 m H2O
  • Integrated internal overvoltage protection circuit
  • Marine certificate

Specifications

Certifications & Approvals

  • ATEX
  • DNV

Accuracy

  • 0.2 % FSO

Thermal Error

  • Typical 0.3 % / 10° C, max. 0.4 % / 10° C
  • Typical 0.2 % / 10° C, max. 0.3 % / 10° C

Long Term Stability

  • 0.1 % or 1 cm H₂O for 1 year

Thermal Compensation Range

  • 0° to 40° C

Medium Temperature

  • -30° to 40° C

Measuring Range

  • 2 to 20 mH₂O

Output Signal

  • 4-20 mA

Power Supply

  • 8-36 Vdc

Diaphragm Material

  • Hastelloy

Case Material

  • Hastelloy

Cable Shield

  • ETFE

Environmental Protection

  • IP68

  • Measure Liquid Levels in Tanks in Seawater or Chemical Applications